undefined
FCOM PRO-ABN-SMOKE P 1โ4, 14โ16 ยท FCTM PR-AEP-SMOKE
SMOKE / FUMES / AVNCS SMOKE
- Applies when
- Smoke or fumes are perceived, or the AVIONICS SMOKE alert comes on; LAND ASAP
- At once
- Oxygen masks if needed, 100 % and EMERG; BLOWER and EXTRACT OVRD; CAB FANS off; GALY & CAB off; SIGNS on; contact with the cabin
- Source obvious and reachable
- Isolate the faulty equipment
- Source not isolated
- Divert, and descend to FL 100 or the minimum safe altitude
- Smoke the greatest threat
- Consider the smoke removal procedure, and the emergency electrical configuration
- Unmanageable
- Consider an immediate landing
- Air conditioning suspected
- APU BLEED off; BLOWER and EXTRACT back to AUTO; PACK 1 off, then PACK 1 on and PACK 2 off
- Cabin equipment suspected
- EMER EXIT LIGHT on; COMMERCIAL off; find and isolate the equipment
REMOVAL OF SMOKE / FUMES
- First
- EMER EXIT LIGHT on; CAB FANS off and PACK FLOW HI; LDG ELEV 10,000 ft; descent to FL 100
- Fuel vapours
- CAB FANS on and both packs off instead
- At FL 100
- Packs off; MODE SEL MAN; V/S CTL full up; RAM AIR on at 1 psi or less
- Smoke persists
- 200 kt at most; cockpit door open; headsets on; PM sliding window open
SMOKE / FIRE FROM LITHIUM BATTERY
- Flames
- PF on oxygen, 100 % and EMERG; PM with the smoke hood and the extinguisher
- No flames, device can be moved
- To the cabin
- No flames, device cannot be moved
- Water or a non-alcoholic liquid poured on it; device watched
- Other ECAM smoke alerts, such as cargo: the ECAM procedure first, then this one if needed.
- Packs stay on and ventilation is not reduced to smother a fire; passenger masks stay up if a fire is suspected in the cabin.
- With BLOWER and EXTRACT both on OVRD, one pack may not hold the cabin pressure.
- Smoke from the vents at first points to the air conditioning; several smoke alerts soon follow.
- After an engine or APU failure, smoke can arrive through the bleeds and recirculate until it clears.
- A smell of orange peel suggests a toxic rain repellent leak; pine needles, a harmless one.
- Lithium battery: control goes to the pilot on the side away from the fire if needed, and the cabin crew prepare to store the device.
A portable electronic device catches fire in the cockpit. The flames have been put out but the device cannot be removed from the cockpit. What does the SMOKE / FIRE FROM LITHIUM BATTERY procedure call for?
Practise every system