Who feeds what
FCOM DSC-24-10-20 P 1–2 · DSC-24-10-30-20 P 1 · DSC-24-10-30-30 P 1–6 · DSC-24-20 P 1–5, 11–18
ELEC page
ELEC panel. Dim legends are lights that are out.
- AC BUS 1
- GEN 1GEN 2Not poweredGEN 1Not powered
- AC BUS 2
- GEN 2GEN 2GEN 2GEN 2Not powered
- AC ESS
- AC BUS 1AC BUS 1AC BUS 2AC BUS 1EMER GEN
- DC BUS 1
- TR 1TR 1DC BUS 2, after 5 sTR 2Not powered
- DC BUS 2
- TR 2TR 2TR 2TR 2Not powered
- DC BAT
- TR 1TR 1DC BUS 2, after 5 sTR 2Not powered
- DC ESS
- TR 1TR 1ESS TRESS TRESS TR
- ESS TR and EMER GEN show only their name while their contactors are open. The batteries are off line once charged.
- GEN 2 feeds both AC buses through the bus tie, and part of the galley load is shed. With the APU running, APU GEN takes AC BUS 1 instead.
- AC ESS FEED on ALTN, pressed or switched automatically where fitted: AC BUS 2 feeds AC ESS, and the ESS TR feeds DC ESS.
- The TR 1 contactor is open. TR 2 takes over DC BUS 1 and DC BAT, and the ESS TR feeds DC ESS.
- Both AC buses lost above 100 kt: the RAT drives the EMER GEN. Amber is not powered.
- On the panel, each generator shown OFF has its OFF light on. ALTN lights only when pressed.
- Each generator alone can supply every bus, except the entertainment bus where fitted. Generators never run in parallel: one source per AC bus.
- Each GCU controls its generator's voltage and frequency and opens its line contactor on a fault.
- AC network
- 115/200 V, 400 Hz, three phase
- DC network
- 28 V
- GEN 1, GEN 2
- 90 kVA each, through the IDG
- APU GEN
- Same as an engine generator
- EMER GEN
- 5 kVA, blue hydraulics from the RAT
- Static inverter
- 1 kVA, 115 V single phase, from BAT 1
- TR 1, TR 2, ESS TR
- 28 V DC, up to 200 A
- BAT 1, BAT 2
- 23 Ah each
Priority and bus tie
FCOM DSC-24-10-30-10 P 1 · DSC-24-10-30-20 P 1 · DSC-24-20 P 3–4
- First
- GEN 1 and GEN 2
- Then
- EXT PWR, when its pushbutton is ON
- Last
- APU GEN
- AC ESS BUS, normal
- From AC BUS 1
- DC BUS 1, DC BAT, DC ESS
- From TR 1
- DC BUS 2
- From TR 2
- Each engine generator feeds its own AC bus through its line contactor.
- BUS TIE in AUTO: the bus tie contactors open or close to keep both AC buses powered.
- One contactor closes when one engine generator runs and APU GEN or external power feeds the other side.
- Both close on a single generator, on APU GEN alone or on external power alone.
- The batteries connect to the DC BAT bus only to charge. Most of the time they are off line.
Failures
FCOM DSC-24-10-30-30 P 1–4
| Failure | What takes over |
|---|---|
| One engine generator | APU GEN if available, otherwise the other engine generator |
| AC BUS 1 | AC BUS 2 feeds AC ESS through AC ESS FEED. ESS TR feeds DC ESS |
| AC BUS 1, after 5 s | DC BUS 2 feeds DC BUS 1 and DC BAT |
| One TR | The other TR. ESS TR feeds DC ESS |
| TR 1 and TR 2 | ESS TR feeds DC ESS. DC BUS 1, DC BUS 2 and DC BAT are lost |
- One generator lost: part of the galley load is shed automatically.
- A TR contactor opens on overheat or minimum current.
- AC ESS FEED to ALTN by hand. Some aircraft switch automatically.
Emergency generation
FCOM DSC-24-10-30-30 P 5–12 · DSC-24-20 P 7–8
- RAT extends
- AC BUS 1 and 2 lost, above 100 kt
- EMER GEN drive
- Blue hydraulics, hydraulic motor
- EMER GEN feeds
- AC ESS, DC ESS through ESS TR
- Coupling
- 3 s after the RAT drives it
- Gap on batteries
- About 8 s
- Manual extension
- RAT MAN ON (guarded)
- RAT & EMER GEN FAULT, red: EMER GEN not supplying while AC BUS 1 and 2 are unpowered.
- Green EMER GEN memo while it runs.
- RAT stalls: blue pressure is lost and the batteries take over, as below.
- Smoke drill: GEN 1 LINE to OFF, then the same network as emergency generation, but with the fuel pumps kept upstream of the GEN 1 line contactor.
- About 75% of equipment is shed in the smoke configuration.
Batteries and static inverter
FCOM DSC-24-10-20 P 2 · DSC-24-10-30-30 P 5 · DSC-24-20 P 2
- BAT 1 feeds
- Static inverter: AC STAT INV, AC ESS above 50 kt
- BAT 2 feeds
- DC ESS
- Inverter above 50 kt
- Automatic, whatever the BAT pushbuttons
- Inverter below 50 kt
- Only with both BAT pushbuttons on
- Charging starts
- Below 26.5 V
- Charging ends
- Below 4 A
- Charging delay in flight
- 30 min
- APU start with EMER GEN running
- Batteries connected 3 min maximum
- On batteries only the AC and DC ESS SHED buses are shed.
- On the ground below 100 kt the DC BAT bus reconnects to the batteries, and the APU can be started.
- Below 50 kt the AC ESS bus is shed and every display unit goes dark.
- On the ground with the BAT pushbuttons in AUTO, the batteries cut off when main power is removed and their voltage is low. OFF then AUTO resets them.
Overhead panel
FCOM DSC-24-20 P 1–8 · DSC-24-10-20 P 3
| Pushbutton | FAULT light |
|---|---|
| BAT 1, BAT 2 | Charging current outside limits; the contactor opens |
| IDG 1, IDG 2 | Oil outlet above 180 °C or low oil pressure |
| GEN 1, GEN 2, APU GEN | GCU trip, or line contactor open with the switch ON |
| AC ESS FEED | AC ESS bus not supplied |
| GALY & CAB | Any generator above 100% load |
| RAT & EMER GEN | EMER GEN not supplying with both AC buses lost |
- IDG disconnect: press 3 s at most, only with the engine running or windmilling. Only maintenance can reconnect it.
- The IDG disconnects itself at 200 °C.
- GEN reset has no effect after two attempts on a differential fault.
- EXT PWR ON stays lit even when the engine generators take over.
- Green, monitored circuit breakers out for over 1 min trigger C/B TRIPPED. Wing tip brake breakers have red caps and must not be reset.
ELEC page: when values turn amber
FCOM DSC-24-20 P 10–20
- Battery voltage
- Below 25 V or above 31 V
- Battery discharge
- Above 5 A
- TR voltage
- Below 25 V or above 31 V
- TR current
- 5 A or less
- Generator voltage
- Below 110 V or above 120 V
- Generator frequency
- Below 390 Hz or above 410 Hz
- Generator load
- Above 100%
- IDG oil outlet
- Pulses above 147 °C, amber above 180 °C
- The same voltage and frequency limits apply to APU GEN, EMER GEN, external power and the static inverter.
- SHED appears when the AC or DC ESS SHED bus is shed.
- GALLEY SHED: GALY & CAB OFF, or the main galleys shed with one generator left.
- Electrical ECAM messages explained
Quick · Electrical
5 free questions
Electrical
With BUS TIE in AUTO and the APU generator unavailable, what happens if GEN 1 becomes inoperative?
Practise all 103 Electrical questions
Free includes five Electrical questions with no account or payment card required. Premium costs CHF 19/month and unlocks all 2,069 A320Q questions across 20 categories in Quick, Exam and Streak modes.
Questions about the A320 electrical system
When does the RAT deploy automatically on the A320?
The RAT extends automatically when AC BUS 1 and AC BUS 2 are both lost and the aircraft speed is above 100 kt. It pressurises the blue hydraulic system, which drives the emergency generator. The crew can also extend it with the guarded MAN ON pushbutton.
What stays powered on batteries only?
Battery 1 feeds the static inverter, which supplies the AC STAT INV bus and, above 50 kt, the AC ESS bus. Battery 2 supplies the DC ESS bus. The AC and DC ESS SHED buses are shed and the hot buses stay powered.
What does the AC ESS FEED pushbutton do?
In normal operation AC BUS 1 supplies the AC ESS bus. Selecting ALTN supplies it from AC BUS 2 instead, for example after AC BUS 1 is lost. Some aircraft switch automatically. The FAULT light means the AC ESS bus is not supplied.
Which generator has priority on the A320?
An engine generator always has priority. External power comes next, ahead of the APU generator, once the EXT PWR pushbutton is ON. The generators never run in parallel, so each AC bus has a single source at any time.