Three systems
FCOM DSC-29-10 P 1–3 · DSC-29-20 P 1–3, 9–11 · DSC-29-10-30 P 1 · DSC-27-10-20 P 1 · PRO-ABN-HYD
HYD page
HYD panel. Dim legends are lights that are out.
- Flight controls
- Engine 1 pump: Normal lawGreen lost: Normal lawBlue lost: Normal lawYellow lost: Normal lawGreen + blue: Alternate law, no protections. Direct law once the gear is downGreen + yellow: Alternate law. Direct law once the gear is downBlue + yellow: Normal law
- Landing gear
- Engine 1 pump: NormalGreen lost: Gravity extension, no retractionBlue lost: NormalYellow lost: NormalGreen + blue: Gravity extension at 200 ktGreen + yellow: Gravity extension once in CONF 3 at VAPPBlue + yellow: Gravity extension, to preserve green
- Brakes
- Engine 1 pump: NormalGreen lost: Alternate (yellow) with anti-skidBlue lost: NormalYellow lost: NormalGreen + blue: Alternate (yellow)Green + yellow: Yellow accumulator only: 7 full applications, 1,000 PSI maximumBlue + yellow: Normal
- Also lost
- Engine 1 pump: Nothing elseGreen lost: AutobrakeBlue lost: Nothing elseYellow lost: Nothing elseGreen + blue: AP 1 and 2, autobrakeGreen + yellow: AP 1 and 2, autobrake, anti-skidBlue + yellow: AP 1 and 2
- Landing
- Engine 1 pump: Normal. Landing distance procedure on the neoGreen lost: Landing distance procedureBlue lost: Landing distance procedureYellow lost: Landing distance procedureGreen + blue: Flap lever 3, VREF + 25 kt (more on some aircraft)Green + yellow: Flap lever 3, VREF + 25 kt (more on some aircraft)Blue + yellow: Landing distance procedure
- Green alsoLanding gear, normal brakes, yaw damper 1
- Blue alsoEmergency generator
- Yellow alsoAlternate and parking brake, nose wheel steering, yaw damper 2, cargo doors (hand pump)
- All three run continuously, each with its own reservoir and accumulator. White triangles: RAT stowed, yellow electric pump off.
- Fluid never passes between systems. The PTU moves power, not fluid, when green and yellow differ by more than 500 PSI.
- Priority valves cut heavy users at low pressure: gear, slats and flaps on green; slats and emergency generator on blue; flaps on yellow.
- HYD G ENG 1 PUMP LO PR: the PTU runs and yellow pressurises green. Filled arrows point to the system it supplies.
- Shown before the ECAM action. GREEN ENG 1 PUMP OFF turns LO into an amber cross line.
- Failures are shown for a reservoir at low level, with the ECAM actions done: on the panel, FAULT is out and OFF is on. A green or yellow engine pump failure alone is covered by the PTU.
- Double failures: land as soon as possible, maximum 320 kt / M 0.77 on most aircraft, go-around pitch 15° maximum, TOGA then MCT.
- Speed brakes are not used after green + blue or blue + yellow.
- Lost by RSVR LO AIR PR: may come back lower down. By RSVR OVHT: may come back once OVHT clears.
Power transfer unit
FCOM DSC-29-10-20 P 1 · DSC-29-20 P 2–3, 11 · PRO-ABN-HYD P 75
- Links
- Green and yellow, both directions
- Runs in AUTO
- Green and yellow differ by more than 500 PSI
- First engine start
- Inhibited
- Second engine start
- Tested automatically
- PTU OFF
- Both PTU valves close, no transfer
- Memo
- HYD PTU, green, while it runs
- With engines stopped, the yellow electric pump can pressurise green through the PTU.
- Blue is never connected to the PTU.
- HYD PTU FAULT: on ground, PTU not running above 650 PSI difference; in flight, not running with green or yellow at low level and low pressure.
- Green or yellow reservoir at low level and low pressure: PTU OFF.
RAT and electric pumps
FCOM DSC-29-10-20 P 1–2 · DSC-29-20 P 1–4, 11 · PRO-ABN-HYD P 42
- RAT extends
- AC BUS 1 and 2 both lost
- RAT by hand
- RAT MAN ON, at any time
- RAT pressure
- 2,500 PSI, blue only
- Minimum RAT speed
- 140 kt
- RAT stowed
- Only on the ground
- RAT OUT memo
- Green, amber in flight phases 1 and 2
- Blue pump in AUTO
- In flight, or on ground with one engine running
- Yellow pump
- ON by pushbutton, or by the cargo door selector
- The RAT keeps blue alive after a total electrical loss or both engines out. Blue then drives the emergency generator.
- On the ground, BLUE PUMP OVRD on the maintenance panel runs the blue pump with engines stopped.
- Cargo door selector to OPEN or CLOSE starts the yellow pump and blocks other yellow users, except alternate braking and reverser 2.
- After a power cut, the yellow pump stays off until selected again.
Reservoirs, valves and accumulators
FCOM DSC-29-10-20 P 2–4 · PRO-ABN-HYD P 4, 35
- Reservoir pressure
- HP bleed air from engine 1
- Bleed too low
- Taken from the crossbleed duct
- Why pressurised
- So the pumps do not cavitate
- Accumulators
- One per system, for transient demands
- Fire shutoff valves
- Green and yellow, upstream of the engine pump
- Closed by
- ENG 1 or ENG 2 FIRE pushbutton
- Leak measurement valves
- One per system, upstream of the primary flight controls
- Closed by
- Maintenance panel only
- Cavitation gets more likely with altitude, which is why a low air pressure loss can recover after descent.
- Case drain filters on the engine pumps and blue electric pump show pump wear to maintenance.
- After a yellow failure the parking brake may be lost, as its accumulator pressure drops.
Overhead panel
FCOM DSC-29-20 P 1–4
| Pushbutton | FAULT light |
|---|---|
| ENG 1, ENG 2 PUMP | Reservoir low level, overheat or low air pressure; pump low pressure |
| BLUE ELEC PUMP | Same, plus pump overheat |
| YELLOW ELEC PUMP | Same, plus pump overheat |
| PTU | Green or yellow reservoir overheat, low air pressure or low level |
| RAT MAN ON | No FAULT light |
- Selecting OFF puts a FAULT light out, except an overheat, which stays lit while it lasts.
- Pump low pressure is inhibited on the ground with the engine stopped.
- ENG PUMP OFF depressurises the pump, so that system stops generating.
- BLUE ELEC PUMP and BLUE PUMP OVRD are guarded.
HYD page and alerts
FCOM DSC-29-20 P 9–11 · PRO-ABN-HYD P 9, 41
- System pressure amber
- Below 1,450 PSI
- Dual SYS LO PR alert
- 1,450 PSI or less, resets at 1,750 PSI
- ENG PUMP LO PR alert
- Pump outlet 1,750 PSI or less, resets at 2,200 PSI
- Fire valve, amber cross line
- Fully closed
- PUMP legend amber
- N2 below idle
- Engine pump, amber LO
- Pushbutton ON, pressure low
- ELEC legend amber
- Power supply to that pump lost
- RAT amber
- Stow pressure applied, or RAT pump not available
- Engine pump cross line, amber: its pushbutton is OFF.
- Reservoir quantity turns amber below the low level mark. LO AIR PRESS and OVHT show under the reservoir.
- The PTU arrow shows which way it is pushing: towards green or towards yellow.
- Hydraulic ECAM messages explained
Quick · Hydraulics
5 free questions
Hydraulics
Which hydraulic systems have a pump that is driven by an engine?
Practise all 102 Hydraulics questions
Free includes five Hydraulics questions with no account or payment card required. Premium costs CHF 19/month and unlocks all 2,039 A320Q questions across 20 categories in Quick, Exam and Streak modes.
Questions about the A320 hydraulic system
Which pumps pressurise the three A320 hydraulic systems?
Engine 1 drives the green pump and engine 2 drives the yellow pump. Blue has an electric pump, with the RAT as its emergency source. Yellow also has an electric pump and a hand pump for the cargo doors. Fluid never passes from one system to another.
When does the A320 PTU run?
With its pushbutton in AUTO, the PTU runs by itself when the pressure difference between green and yellow is more than 500 PSI. It works in both directions. It is inhibited during the first engine start and tested during the second.
What is lost with a green and blue hydraulic failure?
Flight controls go to alternate law without protections, then direct law once the gear is down. The left elevator, both ailerons, spoilers 1, 3 and 5, the slats and both autopilots are lost. The gear is extended by gravity at 200 kt and the aircraft lands with flap lever 3.
Why is the landing gear extended by gravity after a green system loss?
Only the green system drives the landing gear. With green lost, the gear can only come down by gravity and can no longer be retracted. After a blue and yellow failure the FCOM also asks for gravity extension, to keep the green system intact.